Part Number: ETI0003-1066
Model: ETI0003-H/60/120
Rugged Rackmount Power Distribution Unit

Industrial Standard Product
PowerStationETI0003-H Configuration 
60 Amp Rugged Rack Mount PDU w/ 6 Circuit, 2 Pole,
Intelligent, Solidstate Controls and Remote Control Panel
Safety and Thermal Interlocks

ETI0003-H PDU Front View
ETI0003-H/60/120 Standard Front Panel Layout

ETI0003-H PDU Rear View
ETI0003-H/60/120 Standard Rear Panel Layout

The field proven PowerStation™ Power Distribution Unit (PDU) line is ideally suited for industrial and telecommunications applications requiring a rugged rack, vehicular or field deployable, high reliability, compact size and light weight design. The heavy-duty chassis occupies only 2U (3.5”) of rack space while controlling up to 7200 VA of power via six double pole controls. The rounded metal corners and rugged handles aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. All controls and protective devices are brought to the front panel with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The display/control panel contains individual control switches, alarm silence switch and alarm LEDs.

The LED arrays keep the operator informed as to the unit's status. An alarm will flash its respective LED until acknowledged. Once the alarm reset is pressed, the LED will remain on steady until the alarm is cleared. The intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus battleshort override. Each load can have an external interlock to turn off power to equipment when it is not fully engaged in the rack or becomes overheated. The rack may be equipped with both a thermal warning and a thermal shutdown sensor that the PDU uses to alarm and shut down all the loads to avoid damage or thermal runaway. A battleshort signal will override both the thermal and interlock signals. An external CPU Fail or auxiliary alarm signal can also brought in to annunciate. The display and control panel can be mounted remotely in the rack, or on the keyboard console, or on the unit front panel with only a logic level cable connection. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. The double pole input breaker provides overload and short circuit protection for the connected loads. The optional Emergency Power Off (EPO) function can remotely open the input circuit breaker. Each load is controlled by a double pole solidstate relay avoiding accidental operation due to shock or vibration. The elapsed time hour meter tracks the rack equipment operation for maintenance. 

The rear panel provides locking connectors for the input power, output power, alarm and control signals. Appropriate jumper plugs are available for options not used in a particular rack system.

Overall, the PowerStation product line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications

AC INPUT FROM RACK
PDU input from rack: 120 VAC nominal, optional up to 600 VAC
INPUT MAIN (J1) connection: MS3102A32-17P, 4 pin locking
Input control/protection: Guarded 2 pole, 60 amp circuit breaker
Input power indicator: Green neon lamp
AC OUTPUT TO FANS
PDU output to fans: Same as input from rack
AC TO FANS (J4) connection: AMP CPC Type XII, 3 socket reverse, locking
POWER DISTRIBUTION
PDU output voltage to loads: Same as input from rack
Output rating to loads: Limited to lesser of 20 amps or 60 amps total
Output circuits: Six controlled outputs w/2 pole ss relays
LOADs (J5-J8, J15-J16) IEC-320-F w/cable restraint standard
THERMAL CONTROL
Control function: Two stage thermal warning and shutdown
THERMAL CONTROL (J9): AMP CPC Type III, 9 pin locking
INTERLOCK CONTROL
Control function: Microswitches sense each equipment position
Disconnects power to load when racked out
INTERLOCK (J10) connection: AMP CPC Type III, 16 pin locking
REMOTE CONTROL
Output control/alarm silence: Local/remote control panel w/rocker switches
Operational status: LEDs for WARM, HOT, CPU
Adjustable +90 dB audible alarm
REMOTE CONTROL (J11) connection: DB-25 female with locking mount
CPU INTERFACE
Control function: Brings in Battleshort and CPU Fail signals
CPU (J13) connection: DB-9 female with locking mount
MECHANICAL
Dimensions ( H x D x W ): 3.5 (2U) x 12.0 x 19.0 in (89x305x483mm)
Rack Slide Mount Patterns: Slides or rear support mounting brackets
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 20 lb. (9.1 kg) with lift handles front
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: Convection cooling
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C )
Operating temperature: 32° to 122° F ambient (0° to 50° C ), higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 10,000 ft (3,048 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard,
MIL STDs 901, 167 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 safety requirements
EMI Protection: EMI/RFI FCC, Class B, MIL STD 461
OPTIONAL ACCESSORIES
  Dual Source Input, Emergency Power Off, EMI Insertion Loss Filters, Auxiliary DC Power Supply, MS Connectors, Transient Surge Suppression, Load Sequencing