Part Number: ETI0001-1235 
NSN: 6130-01-456-5656
NSWC Rugged Industrial 1000 VA UPS and 
28 VDC Power Source with
Dual Source Input and Cold Start

Naval Surface Warfare Center Control System
Rugged Industrial Rack or Fixed Mount 1.0 kVA AC and DC UPS
W/Dual Source Input and External Battery Module

P/N: ETI0001-1235 Rugged MilSpec UPS Standard Front Panel Layout
P/N: ETI0001-1235 Rugged Industrial UPS Standard Front Panel Layout
NSN: 6130-01-456-5656

P/N: ETI0001-1235 Rugged MilSpec UPS Standard Rear Panel Layout
P/N: ETI0001-1235 Rugged Industrial UPS Standard Rear Panel Layout

The field proven PowerStation™ UPS line is ideally suited for industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in fixed locations with controlled or uncontrolled environments. 

The heavy-duty chassis, occupying only 5.25” (3U) by 23.5” depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. 

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent. To provide added flexibility and reliability, the “ETI0001-1235” accepts two independent AC power sources and includes inrush current limiting. The UPS can operate from either power source automatically and does not use its battery unless both sources have failed.

The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60 hertz power. The “ETI0001-1235” has the added benefit of having an internally redundant 28 VDC DC power source output. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent. 

The rear panel provides locking connectors for the input and output power. Removable and washable air filters and a high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vents, with alternate air flow directions optional. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series section for versions of UPS with an integrated PDU and remote control.

Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N: ETI0001-1235
NSN: 6130-01-456-5656

AC OUTPUT
Output voltage: 120 VAC true sinewave std, up to 600 VAC optional
Output rating: UPS 1000 VA 0.65-0.75 pf standard including DC output
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 1.0% independent of input frequency
50, 400 or 1000 Hz output available as an option
Operational status Status, load and battery LEDs, w/contacts
+90 dB audible alarm, alarm on/off inhibited
DC OUTPUT
Output voltage / rating: DC 28 VDC / 300 watt
Output voltage regulation: ± 2.0% static regulation of nominal
Overload surge capacity: 110% continuously
Output protection: Front panel mounted fuse (DC)
AC INPUT
Input voltage selection: Dual Source Input, two separate AC sources, J1A and J1B
Nominal 120 VAC, optional autoranging input of 85-270 VAC
Input voltage tolerance: UPS 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: 1000 VA, up to 120 dB common mode, 1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole switch (S1) w/fuse (F2A and F2B)
Cold start to turn on w/o AC present
Input power connections: Two MS 3102A-22-2P, 3 pin, locking
EXTERNAL BATTERY
External battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
External battery life: Rated for continuous service life of 5 years
External DC protection: Front panel mounted fuse (F1)
DISTRIBUTION PANEL
Output circuits: One AC and one DC outputs standard
Output control: Optional remote control panel w/rocker switches
Output receptacles: AC output 
DC output 
MS3102A22-2S, 3 pin locking standard, various options
MS3470W14-5S, 5 pin locking standard
MECHANICAL
Dimensions (H x D x W): 5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: 88 lb. (40 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C)
Operating temperature: 32° to 126° F ambient ( 0° to 52° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 
OPTIONAL ACCESSORIES
  Autoranging International Input, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits