heading

Model: ETI0014-D4 Series
MissionCritical™ Rugged 
Rackmount Drive Expansion Unit

Industrial Standard Product
12 Slim or 8 Half or 4 Full Height Bays
Redundant Power Supplies

ETI0014-D4 Front Panel Layout
>ETI0014-D4 Front Panel Layout (Shown with Front Panel 1 - (4) Half Height Removable Media Drive Bays)

ETI0014-D4 Rear Panel Layout
>ETI0014-D4 Rear Panel Layout (Shown with Various SCSI Connector and ID Panel Options)

The MissionCritical™ ETI0014-D4 (D4 for short) is ideally suited for critical applications requiring rugged rack or table mount and/or portable construction, high reliability, compact size and light weight design. The heavy duty chassis occupies only 3U of rack space while accommodating up to four full height, shock mounted, mass storage bays each powered by redundant 65 watt power supplies. Each bay can have mounted either one full height or two half height or three slim height devices. The front panels provide access to either two full height or four half height devices with removable media (i.e. floppy disks, tape cartridges, CD-ROMs, or optional drive shuttles). The rounded metal corners and rugged handles, aid in safe handling. The chassis has threaded inserts for four of the more commonly used rack slides. The optional mounting kit includes flanges and legs for horizontal or vertical mounting other than rack. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. Additionally each drive bay is shock mounted within the chassis. The universal input selects from either domestic or international voltages automatically. The LED arrays keep the operator informed as to the power and activity status of each device. Controls and protective devices are brought to the front control panel which is recessed to prevent damage or accidental operation. The input switch, fuses and wiring provide double pole isolation for shipboard systems. A bi-directional single-ended to differential SCSI converter option allows the mixing of both single-ended and differential SCSI devices on one SCSI bus. This option is available for either Fast SCSI-2 or Fast-Wide SCSI-2 and SCSI-3.

The rear panel provides four interface panel positions. Interface panel options are available for all standard SCSI connectors. These can be mixed and matched to suit a particular configuration. An optional SCSI ID selector switch panel allows external setting of device IDs. Dual washable intake air filters and high capacity ball bearing fans provide added protection in both controlled and hostile environments. The cooling air is diverted out the front vents after passing by both top and bottom of each device.

Overall, the MissionCritical™ line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications
DRIVE BAYS
Drive bays type: (4) full height bays, any bay can hold up to
(2) half height or (3) slim height devices
Drive bay mounting: Each full bay shock mounted to chassis
Removable media: Front bays can have fixed or removable media
DRIVE BAY POWER
Drive bay power: Both +5 and +12 VDC to each half height bay
Drive power connector: Both standard and mini power connectors
Drive power control: Recessed, ON/OFF rocker switches, 1 per bay
Drive status indicators: (1) Power, (1) Activity LED per half height bay
DRIVE I/O INTERFACE
I/O Ports: Four chassis input/output (I/O) panels standard
I/O Connectors: Selection of 50 and 68 terminal connectors for
SCSI-2 and SCSI-3, both Fast and Fast/Wide
Other I/O interfaces available upon request
SCSI address selection: Fixed at device by jumper setting standard,
Optional external SCSI ID selector switches (8)
Single-ended/Differential: Can be mixed w/ optional bi-directional converter
AC INPUT
Input voltage selection: 100-240 VAC, 46-70 Hz autoranging, DC optional
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Recessed, double pole, front mounted switch
Recessed, front mounted fuses, 1 per line
Internal AC input fuse on each supply x 4
Input status indicator: AC Power On indicator, green neon
Input power connection: IEC320-15P with cable restraint, others optional
INTERNAL DC SUPPLIES
Output rating: each Redundant 65 watts for each full bay x 4
Output voltage:+5 VDC +5 VDC, 5% tolerance, 50 mV ripple
Output current:+5 VDC 3.5 A max., 0.5 A min., 8 A peak, each supply
Output voltage regulation:+5 VDC 1.0% static, 5.0% dynamic of nominal
Output voltage:+12 VDC +12 VDC, 10%, 100 mV ripple
Output current:+12 VDC 4.0 A max., 0.5 A min., 8 A peak, each supply
Output voltage regulation:+12 VDC 2.0% static, 10% dynamic of nominal
MECHANICAL
Overall Dimensions ( H x D x W ): 5.25 (3U) x 23.5 x 19.0 in (133x597x483mm)
Rack Slide Mount Patterns: Jonathan, General Devices or EMCOR patterns
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 35 lb. (16 kg) with lift handles front and rear
Audible noise: Less than 45 dB @ 5.0 ft., ANSI "A" scale
Cooling type: Dual, high capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front and sides std
Air intake filter: Washable filter media, various porosities
ENVIRONMENTAL
Storage temperature: -4 to 122 F ambient (-20 to 50 C )
Operating temperature: 32 to 122 F ambient (0 to 50 C )
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 10,000 ft (3,048 m), higher optionally
STANDARDS
United States: Meets to UL standard 1950,
MIL STDs 810, 454 & 1399 For Shipboard Use
Canada: CSA requirements 1402C safety requirements
EMI Protection: EMI/RFI FCC, Class A, optional MIL STD 461
OPTIONAL ACCESSORIES
  Alternate mounting kit, Custom configurations

For information on ETI's rugged removable disk drive carriers, check out ETI0014-DE200 that are hot swappable, RAID compatible and withstand shock and vibration.

This page was last modified on: May 04, 2008
The N5 is one of the most popular configurations for new programs!