Part Number: ETI0003-1031
Model: ETI0003-D/30/120
Rugged Rackmount Power Distribution Unit
Industrial, Raytheon Standard
Product
PowerStation™ ETI0003-D
Configuration
30 Amp Rugged Rack Mount PDU w/ 4 Circuit, 2 Pole,
Intelligent, Solidstate Controls and Remote Control Panel
Safety and Thermal Interlocks

ETI0003-D/30/120 Standard Front Panel Layout

ETI0003-D/30/120 Standard Rear Panel Layout
The field proven PowerStation™ Power Distribution Unit (PDU) line is ideally suited for industrial and telecommunications
applications requiring a rugged rack, vehicular or field deployable, high reliability, compact size
and light weight design. The heavy-duty chassis occupies only 2U (3.5”) of
rack space while controlling up to 3600 VA of power via four double pole
controls. The
rounded metal corners and rugged handles aid in safe
handling. Internally, all major components are well secured and electrically
insulated to prevent damage due to shock and vibration. All controls
and protective devices are brought to the front panel with critical switches or
breakers guarded. Further, all front panel devices are recessed to prevent
damage or accidental operation. The
display/control panel contains individual control switches, alarm silence
switch and alarm LEDs.
The LED
arrays keep the operator informed as to the unit's status. An alarm will flash
its respective LED until acknowledged. Once the alarm reset is pressed, the LED
will remain on steady until the alarm is cleared. The intelligent PDU allows control of
the individual output circuits incorporating thermal and interlock interfaces
for additional control and safety, plus battleshort override. Each load
can have an external interlock to
turn off power to equipment when it is not fully engaged in the rack or becomes
overheated. The rack may be equipped with both a thermal warning and a thermal shutdown sensor that the
PDU uses to alarm and shut down all the loads to avoid damage or thermal
runaway. A battleshort signal
will override both the thermal and interlock signals. An external CPU Fail or
auxiliary
alarm signal can also brought in to annunciate. The display and control
panel can be mounted remotely in the rack, or on the keyboard console, or on the
unit front panel with only a logic level cable connection. The high intensity audible alarm can be heard in high noise
environments, yet is easily adjustable to suit quieter conditions. The double pole input
breaker provides overload and short circuit protection for the connected loads. The
optional Emergency Power Off (EPO) function can remotely open the input circuit breaker.
Each
load is controlled by a double pole solidstate relay avoiding accidental
operation due to shock or vibration. The elapsed time hour meter tracks the
rack equipment operation for maintenance.
The
rear panel provides locking connectors for the input power, output power, alarm
and control signals. Appropriate jumper plugs are available for options not
used in a particular rack system.
Overall, the PowerStation product line is uniquely qualified for critical shipboard,
vehicle, airborne or land based systems combining advanced modular design
features with highly reliable construction.
Technical Specifications
AC INPUT FROM RACK |
PDU input from rack: |
120 VAC nominal, optional up to 600 VAC |
INPUT MAIN (J1) connection: |
MS3102A32-17P,
4 pin locking |
Input control/protection: |
Guarded 2 pole, 30 amp circuit breaker |
Input power indicator: |
Green neon lamp |
AC OUTPUT TO FANS |
PDU output to fans: |
Same as input from rack |
AC TO FANS (J4) connection: |
AMP CPC Type XII, 3 socket reverse, locking |
POWER DISTRIBUTION |
PDU output voltage to loads: |
Same as input from rack |
Output rating to loads: |
Limited to lesser of 20 amps per load or 30
amps total |
Output circuits: |
Four controlled outputs w/2 pole ss relays |
LOADs (J5-J8) |
IEC-320-F w/cable restraint standard |
THERMAL CONTROL |
Control function: |
Two stage thermal warning and shutdown |
THERMAL CONTROL (J9): |
AMP CPC Type III, 9 pin locking |
INTERLOCK CONTROL |
Control function: |
Microswitches sense each equipment position
Disconnects power to load when racked out |
INTERLOCK (J10) connection: |
AMP CPC Type III, 16 pin locking |
REMOTE CONTROL |
Output control/alarm silence: |
Local/remote control panel w/rocker switches |
Operational status: |
LEDs for WARM, HOT, CPU
Adjustable +90 dB audible alarm |
REMOTE CONTROL (J11) connection: |
DB-25 female with locking mount |
CPU INTERFACE |
Control function: |
Brings in Battleshort and CPU Fail signals |
CPU (J13) connection: |
DB-9 female with locking mount |
MECHANICAL |
Dimensions ( H x D x W ): |
3.5 (2U) x 12.0 x 19.0 in (89x305x483mm) |
Rack Slide Mount Patterns: |
Slides or rear support mounting brackets |
Alternate Mounting Options: |
Table, Wall, Floor, Portable, Horizontal/Vertical |
Shipping weight: |
20 lb. (9.1 kg) with lift handles front |
Audible noise: |
Less than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling type: |
Convection cooling |
ENVIRONMENTAL |
Storage temperature: |
-13° to 140° F ambient (-25° to 60° C ) |
Operating temperature: |
32° to 122° F ambient (0° to 50° C ),
higher optional |
Operating humidity: |
0 to 95% relative humidity (non-condensing) |
Operating elevation: |
Up to 10,000 ft (3,048 m), higher optionally |
STANDARDS |
United States: |
Meets UL-1778 standard,
MIL STDs 901, 167 & 1399 Shock/Vib/Electrical |
Canada: |
CSA C22.2 No. 107 safety requirements |
EMI Protection: |
EMI/RFI FCC, Class B, MIL STDs 461 |
OPTIONAL ACCESSORIES |
|
Dual Source Input, Emergency
Power Off, EMI Insertion Loss
Filters, Auxiliary DC Power Supply, MS Connectors, Transient Surge Suppression, Load Sequencing |
This page was last modified on: